7 Tips for selecting a subrack - nVent Blog

Author: Vic

Jun. 16, 2025

27

0

Tags: Machinery

7 Tips for selecting a subrack - nVent Blog

Subracks, also known as card cages, are used for the reception of printed circuit boards (PCBs) and plug-in units (PIUs) in many different industries like telecom, transportation, test and measurement, aerospace and defense. For choosing the right subrack for your application, it is essential to be familiar with the fundamental requirements and standards. Check out seven criteria on how to select a subrack.

If you are looking for more details, kindly visit Rdekono.

  • Tip 1: Pay attention to Dimensions
  • Tip 2: Comply with Standards and Specifications
  • Tip 3: Be aware of Environmental Conditions
  • Tip 4: Consider also Static and Dynamic Loads
  • Tip 5: Don’t forget about EMC Shielding 
  • Tip 6: Design aspect – Underestimated, but very powerful
  • Tip 7: Inform yourself about the Integration Levels offered 

Tip 1: Pay attention to Dimensions

The size and type of electronics assemblies determine the dimensions of subracks. Also, the place of operation can lead to the need to meet certain specifications or restrictions.

Using the 19” standard
In general, we recommend the use of commercially available standardized boards that comply with the 19″ standard, as a large number of solutions are available according to these standards. Making use of off-the-shelf products saves the user development time, tooling costs, and no need to keep stock of specific components. Typical dimensions are 3 U and 6 U (height units: 1 U = 1¾ inches).

The downside of using “non-standard” components
For “non-standard” electronic components, such as non-standard printed circuit boards (PCBs), it is vital to ensure that the internal configuration of the subrack allows the inclusion of such non-standard components. If the electronics assemblies are small enough, frame type plug-in units provide compact solutions built into standardized subracks or cases. The external dimensions of the frame-type plug-in units are 19″ compatible and can accommodate both standardized and non-standardized electronic components. This allows non-standardized boards or components to be installed in a chassis or with a mounting plate in the subrack.

Trends influencing dimensions
Thanks to the ongoing miniaturization of components and the growing degree of integration, more than 70% of standardized boards are now produced in 3 U (Euroboard) format. This leads to a trend towards a reduction in the height dimensions of subracks. Another trend emerging is the increased use of active cooling of the boards with high heat dissipation losses using DC or AC blowers. To reduce the noise level during operation, intelligent blowers are becoming popular, which are controlled via system management.

Always consider the environmental conditions
The location where the system is finally installed naturally influences the dimensions of the subrack. Often the space available for installation – e.g., on ships or other vehicles or in data centers – is very limited, so the relevant specifications must be observed.

Tip 2: Comply with Standards and Specifications

Depending on the application, certain international and/or market-specific standards and specifications apply.

Commonly used IEC standards
Current standards contain additional dimension specifications (IEC -1, IEC -2, IEC -3-101, IEC -3-102, IEC -3-103, IEC -2-1, IEC -2-2, IEC -2-X) and – at a higher level – criteria for physical integration (IEC -1, IEC -3), earthquake resistance (IEC -2), electromagnetic compatibility (IEC -3), and thermal management (IEC Ed.1). The ETS standards were defined by ETSI (the European Telecommunication Standardization Institute). ETS standards are closely related to IEC standards, particularly in respect of European telecommunications systems.

Market-specific standards
In addition to IEC standards, there are specifications for specific market segments. For example, VME from VITA (VME International Trade Association) and CompactPCI, MicroTCA, and AdvancedTCA from PICMG (PCI International Computer Manufacturing Group). Also, there are particular standards and guidelines for applications in railroad or military technology, such as welding certifications (EN ), environmental tests (EN ) for railroad systems and shock and vibration testing (MIL 901D) for the navy, etc.

Protection and Safety standards
Also, special protection and safety standards must be considered, such as (to name a few).

  • All conductive elements of a mechanical subrack that are capable of coming into contact with dangerous voltages must be grounded and tested to IEC -1.
  • The mechanical components of an assembly system should be free of sharp edges to prevent injury.
  • The design and materials used for a subrack must also be appropriately selected to avoid the risk of fire.
  • Plastics should conform to the self-extinguishing class as per UL 94 V 0 to V 2, tested to IEC .
  • Due to toxic additives contained in materials of the higher self-extinguishing classes, ISO must also be observed.
  • IEC determines the IP protection classes against the ingress of dust or water and for the protection of persons from hazards inside the subrack. The IP protection class designation contains two digits. The first specifies the protection level against foreign objects (from contact by fingers to the ingress of dust), and the second indicates the protection against the ingress of water.

Tip 3: Be aware of Environmental Conditions

Other essential criteria in selecting a subrack are the physical forces acting on it and the level of electromagnetic shielding required. In measurement, instrumentation, and control systems, the requirements for shock and vibration resistance are generally not particularly high (up to 0 or 3 g). For applications ranging from traffic light control and industrial machine control to measuring systems for research or in accelerator rings, basic subracks are generally sufficient.

Often no EMC shielding is required, as this is provided, for example, by the cabinet in which the subrack is installed. If high deflection forces are expected due to the width of the unit and the heavy built-in parts, more robust designs are required.

Subracks for infrastructure applications, e.g., in passenger information or entertainment systems in railroad systems, on buses or aircraft, or as controllers for loading ramps, may in certain situations have to be shock and vibration resistant from > 5 to 25g. Loads of this kind also occur predominantly in defense systems, e.g., in controllers for target acquisition devices on ships. Applications for this particularly robust subrack include power generation for the control of wind turbines. In this case, the subrack is mounted in the nacelle of the windmill and the shock and vibration influences are similarly high. For these applications, the circuit boards mounted in the subracks are additionally secured with Card-Loks or Wedge-Loks.

Tip 4: Consider also Static and Dynamic Loads

The weight of the installed components is the main cause of static loads. This results in the choice of materials for the assembly system and the construction method – glued, welded or as a one-piece unit. Depending on the application, it may be necessary to fit additional reinforcements or stiffening elements. In the case of mobile use of a subrack, it is usually exposed to different dynamic loads. These different shock and vibration influences near the installation site must be taken into account, e.g., in the vicinity of rotating machines, in railway or traffic facilities, as well as on ships or aircraft. Seismic tests must be carried out prior to installation if the installation site is located in an earthquake zone.

For more Subrack Chassisinformation, please contact us. We will provide professional answers.

Additional reading:
What is an extruder and how does it work? - Bausano

Tip 5: Don’t forget about EMC Shielding 


10 Things to Consider When Buying Carton Erector
Choosing the Right Hydraulic Cylinder for Your Industry: A Buyer's ...

The electromagnetic shielding requirements of electronic devices vary depending on the application and environment in which they are used. This applies not only to high-frequency factors. Shielding is designed to cover electrostatic discharge issues and includes low-frequency capacitive or inductive coupling and cable-related faults, as well as high-frequency electromagnetic interference.

Side, top, and bottom plates, as well as the rear and front panels of subracks, are therefore provided with a conductive surface (passivated, etc.) and are conductively connected to each other via contacts such as stainless steel springs or textile EMC seals.

Each position of the cable entry must also be adequately protected. Standardized EMC tests (VG Part 15) determine whether the EMC shielding measures meet the requirements of a specific application and ensure the reproducibility of this performance level.

The IEC environmental standard also defines tests for the EMC behavior of subracks. Section 3 of IEC outlines the test conditions for subracks in respect of their EMC shielding properties in the frequency range from 30 MHz to 21 GHz and the attenuation values.

The standard is mainly based on IEC and IEC . To determine which degree of shielding is required, the critical interference frequencies must be identified. These tests are usually carried out by the manufacturer of the finished equipment or outsourced to independent external test centers.

Tip 6: Design aspect – Underestimated, but very powerful

Typically, the function primarily determines the appearance of a subrack and whether or not it is installed in an electronics cabinet. If the subrack is installed in the cabinet, the emphasis is clearly on functionality. But the front panel still plays a larger role in the visual design factor. Standard blank panels are available on the market in various sizes and versions.

But only a few manufacturers today have the necessary facilities to carry out individual designs and still efficiently produce panels. Some subrack manufacturers, such as nVent, offer complete service with a broad range of front panels offering paint or multi-color (also digital) printing options. This makes it easy for the customer to design an individual front panel, e.g., adding a logo.

Tip 7: Inform yourself about the Integration Levels offered 

In addition to the basic mechanical assembly, demand for the integration of further components is increasing. At nVent, system integration includes electromechanical and electronic components such as EMC elements, cabling, switches, backplanes, power supply units, monitoring units, and cooling solutions, all in one subrack. As a result, users get a type of plug-and-play product for their 19” technology. nVent undertakes the entire project management and advises the customer from the initial specification and design, purchasing, prototype manufacture, testing, and checking right through to the actual product manufacture, including logistics and after-sales service.

With the EuropacPRO subrack nVent SCHROFF is offering a flexible subrack platform based on the 19” form factor, with a wide variety of possible configurations and modifications.

Subrack

Subrack for installation in 19" rack system of electrical boards and subunit modules,

subrack height in rack units (U) and board height (h):
3U for eurocard cards h = 100 mm
6U for double eurocard cards h = 233.35 mm
9U for cards h = 366.7 mm


Subracks are measured in width according to the HP or TE "horizontal pitch" of 5.08 mm, it represents the positions of the pins in which to mount the board guides. The 19" system mount subracks are 84 HP wide at 426.72 mm +/- 0.4.
Subracks and subunits are designed to hold cards in Eurocard formats with depths of 160, 220, 250 and 280 mm (ask for other sizes).

The depth of the subracks depends on the depth of the board and the type of connector chosen, the connectors are mounted on the board and directly on the rear profiles of the subrack or on a backplane. P = Power card depth
P1 = internal subrack usable space, depends on board depth and connector type
Different combinations of rear profiles and "Z"  bars are possible for direct use with DIN , DIN and MIL-C- connectors.
All our subracks comply with IEC , DIN and are characterized by solidity and construction precision, Surtec 650 anti-corrosion treatment of profiles and side walls, robustness, modularity and compliance with different levels of EMC shielding. Different subrack families for specific needs:

Silver Series: economical and versatile with support profiles with a single threaded hole M5, the alignment and teaming during assembly are made by means of special embossings present in the walls of the subrack.

Gold Series: robust, precise and complete with everything necessary for effective EMC shielding, the support profiles are equipped with two M4 threaded holes that simultaneously guarantee perfect alignment and teaming of the subrack as well as high resistance to vibrations and mechanical stress. This family of products is dedicated and widely used in the railway, military, aerospace, naval sectors. About Us

subrack.eu + armadi-rack.it© are run by M.D.W. srl - About Us

M.D.W. srl Chamber of Commerce, Bologna
REA n°
PI/CF

Legal office:Piazza Minghetti, 4/D
Bologna BO, Italy

Operating office:Via Edmondo De Amicis 7
Casalecchio di Reno BO, Italy

Want more information on Subrack Kit for Backplane? Feel free to contact us.

Comments

0

0/2000

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

Your Name:(required)

Your Email:(required)

Subject:

Your Message:(required)

0/2000